Nitrógeno Total (N) | 0% |
Phosphorus Pentoxide (P205) | 0% |
Potassium Oxide (K20) | 0% |
Hierro (Fe) | 4,60% |
Manganeso (Mn) | 1,25% |
Boro (B) | 0,13% |
Cobre (Cu) | 0,125% |
Molibdeno (Mo) | 0,015% |
Zinc (Zn) | 0,600% |
The industry's standard micronutrient supplement for the last 50 years, now in a convenient, ready-to-mix liquid formulation. Goes from the jug to the tank in one easy step with no slubility issues.
The industry's standard micronutrient supplement for the last 50 years, now in a convenient, ready-to-mix liquid formulation. Goes from the jug to the tank in one easy step with no solubility issues.
Always be aware of media pH and the total amount of the minor nutrients provided to the plant. Liquid STEM is added to Peters fertilizer water soluble products. Liquid STEM commonly used in addition to water soluble blends without micronutrients or to boost the micronutrient levels when standard blends are used at low levels. Liquid STEM is also used as a rescue product to solve micronutrients deficiencies in plants.
One time, corrective application - Apply based on analysis / observations.
Drench (using a 1:100 Injector): add 2 to 8 fl. oz. Peters Professional Liquid STEM per gallon of stock solution.
Drench (using a 1:200 Injector): add 4 to 16 fl. oz. Liquid STEM per gallon of stock solution.
Drench (without an injector): add 2 to 8 fl. oz. Liquid STEM per 100 gal of water.
Foliar Spray - add 2 to 4 fl. oz. Liquid STEM / 100 gal of water
Table 1: Drench / Spray Application Rates | ||||
Low | High | |||
Rate (fl oz Liquid STEM/100 gal) | 2.0 | 4.0 | 6.0 | 8.0 |
Rate (ml Liquid STEM/ 100 gal) | 59 | 118 | 178 | 237 |
Conventional Measure* Rates | ||||
Low | High | |||
1 tsp of Peters Professional Liquid STEM | 8.3 gal. | 4.1 gal. | 2.8 gal. | 2.1 gal. |
1 tbsp of Peters Professional Liquid STEM | 25 gal. | 12.5 gal. | 8.3 gal. | 6.25 gal. |
1 cup of Peters Professional Liquid STEM | 400 gal. | 200 gal. | 133.3 gal. | 100 gal. |
Continuous Feeding - Combine with normal fertilizer program as desired to boost micronutrient levels with every feeding. Apply based on analysis / observations.
1:100 Injectors: Add 3.5 to 10 mls of Peters Professional Liquid STEM per 1 gallons of stock solution.
1:200 Injectors: Add 7 to 20 mls of Peters Professional Liquid STEM per 1 gallons of stock solution.
Tank: Add 3.5 to 10 mls of Peters Professional Liquid STEM per 100 gallons of water.
Table 2: Continuous Feed Rates | |||
Low | Medium | High | |
Rate (fl oz Liquid STEM/100 gal) | 0.12 | 0.24 | 0.34 |
Rate (ml Liquid STEM/ 100 gal) | 3.5 | 7.0 | 10.0 |
The industry's standard micronutrient supplement for the last 50 years, now in a convenient, ready-to-mix liquid formulation. Goes from the jug to the tank in one easy step with no slubility issues.